Cassy-1

Closed aspiration system «Cassy»

Closed sanitation is widely used by healthcare facilities to reduce the risk of spread of STIs and contamination of medical personnel.
Submit a request for a product

Closed sanitation is widely used by healthcare facilities to reduce the risk of spread of STIs and contamination of medical personnel. As part of this concept, the company has taken another fundamental step forward: a new generation of truly closed system with an integrated bacterial filter has been developed. Thanks to its innovative design, the Cassy system is extremely easy to use and offers much greater safety and convenience for patients and medical staff than traditional open aspiration devices.

Cassy closed aspiration systems offer the following features:

  • The product allows tracheal and bronchial sanation without interrupting the ventilator, reducing the risk of complications during the procedure.

The traditional algorithm of tracheobronchial tree (TBD) sanation is accompanied by disconnection of the patient from the ventilator and temporary cessation of artificial lung ventilation, which leads to hypoxia, spread of HBI (nosocomial infection) and other undesirable phenomena.

  • Serves to prevent the spread of nosocomial infection.

The use of closed aspiration systems reduces the risk of airborne infection and related illnesses to the patient and medical staff.

  • Closed aspiration system is equipped with a built-in bacterial filter, installed for up to 72 hours of operation when connected to an intubation tube, breathing circuit, vacuum suction, effectively prevents the penetration of any bacterial flora outside the bag when working with the system.

Purpose:

  • Performing aspiration of the contents of the tracheobronchial tree without interrupting the ventilator
  • To perform TBD lavage and aspirate sampling 

Components of the Cassy closed aspiration system:

 

  1. Double standardized connector
  2. Free-rotating connector for connection to the breathing circuit
  3. Connector for connection to an endotracheal or tracheostomy tube
  4. Disconnecting ring
  5. Flushing port
  6. Isolation valve
  7. Mully type aspiration catheter
  8. Transparent protective sleeve
  9. 10. Color-coded connector
  10. Vacuum control unit
  11. Transparent protective cover
  12. Universal male connector
  13. Corrugated stretchable adapter tube

The double standardized swivel connector (1) through the freely rotating connector (2) (prevents twisting of the breathing tubes) allows connection of any breathing circuit design.

The endotracheal or tracheostomy tube connector (3) has a unique disconnecting ring (4) that allows the Cassy to be easily disconnected from the endotracheal or tracheostomy tube. When rotated in the direction indicated by the arrows, the ring gently disconnects the system, without force or the use of special devices.

The flushing port (5) is used to flush the catheter and administer drugs and solutions. It is a tube with a Luer-type connector with a hermetically sealed cap that can withstand repeated opening and closing. Includes a built-in non-return valve to prevent unwanted backflow of the injected solution.

The device is provided with a special isolation valve (6) which, when in the open position, simultaneously with the administration of the solution, allows the insertion of an aspiration catheter into the tube. When the valve is closed, the catheter can be flushed without fear of the flushing solution entering the patient's airway.

A convenient handle clearly indicates the open/closed position of the flushing chamber valve. Moreover, the isolation valve reduces dead space and prevents inadvertent insertion of the catheter into the endotracheal or tracheostomy tube.

A high quality Mully type aspiration catheter (7) protected by a transparent sleeve (8) has:

  • a radiopaque contrast strip
  • markings for catheter retrieval, indelible scale marked on the catheter from 5 cm to 35,45,55 cm (depending on the version) in 1 cm increments, which allow controlling the optimal depth of catheter insertion.
  • the distal end is rounded and provides painless insertion
  • large atraumatic opening at the distal end of the catheter, which effectively removes sputum, two small control side openings are designed to prevent damage to the tracheal mucosa if the distal opening is blocked at any point.

A transparent, thin but durable protective sleeve (8) securely keeps the system sealed. Allows staff to easily manipulate the catheter and visually monitor the color of the secretion, and provides an opportunity to easily read the markings on the aspiration catheter.

Color-coded connectors (9,10) allow quick and easy selection of the desired size Cassy sealed aspiration system.

The vacuum control unit (11) is ergonomically designed for a firm but comfortable grip. The system is equipped with a protection mechanism against accidental activation of the button. The transparent protective cover (12), prevents unintentional pressing of the control button.

The unique 5µ hydrophobic filter integrated into the vacuum control unit, located at the distal end of the Cassy system protective sleeve, effectively prevents any bacterial flora from entering the sleeve.

The universal connector (male type) (13) in the vacuum control unit is compatible with all vacuum aspiration systems and sputum sampling devices. It is reinforced with transverse stiffeners for a secure connection to the vacuum aspirator tube.

The system is equipped with a corrugated stretchable adapter tube (14) for connecting the breathing circuit. The adapter tube is 15 mm / 22 mm.

The included day-of-week labels affixed to the Cassy indicate the day on which the system must be replaced.

All working parts of the product are marked in gray for easy identification.

ITEM NUMBER SIZE, СН  LENGHT, CM

CONNECTOR COLOR IN COMPLIANCE INTERNATIONALLY CODED

NECESSITY CORRUGATED TUBE SET 

Self-adhesive label for labeling the system (replacement date)

PACKAGING/piece
 36001604  6

35

green

+

20

36004604  8

35

blue

+

20

36005604  8

45

blue

+

20

36019604  10

35

black

+

+

20

36021604  10

55

black

+

+

20

36022604  12 

35

white

+

+

20

36024604  12 

55

white

+

+

20

36025604  14 

35

green

+

+

20

36027604  14 

55

green

+

+

20

36028604  16 

35

orange

+

+

20

36030604  16 

55

orange

+

+

20



ETT size (inner diameter, mm) Recommended size Cassy (СН)  Catheter size (outer diameter, mm) 
4,0-4,5  6 2,0 
5,0-6,0  8 2,7 
6,5-7,0  10 3,3 
7,5-8,0  12 4,0 
8,5-9,0  14 4,7 
9,5-10,0  16 5,3 

Specification:

Catheter material polyvinyl chloride.

Other components: acrylonitrile butadiene styrene, polypropylene, silicone, polyurethane, PVC, silicone elastomers, polycarbonate, polyethylene, barium, polytetrafluoroethylene, styrene, acrylonitrile.

Filter: 5µ hydrophobic.

Latex-free.

Sterile, designed for single use.

Has individual sterile packaging with plastic backing (minimizes the risk of damage to the product during storage).

Period of preservation of sterility of the products is 3 years from the date of production.

Sterilized with ethylene oxide.

© . All rights reserved.
Medivice.